6-14
FRX8000 3. 0 User G uide, Rev 02
E1 LP Parameters
1
Displayed only if CRC-4 is disabled.
LP Type
Although pressing
[?]
for help displays a range of
1–6
, the supported types are:
3
= AST Card
4
= T1/E1
6
= RLP-7000 Node
Model Type
Although pressing
[?]
for help displays a range of
0–3
, only
2
is valid for E1 LP.
Coding
is the line coding technique used to carry clock signals.
Framing
is the frame format. G.704 is a CEPT standard, with a set value.
Line Service
specifies whether the LP will use all (Full) or some (Fractional) of the DS0 channels
on a T1/E1 line:
0
= Full,
1
= Fractional
Line Build Out
is the distance from the LP to the external T1/E1 device. G.703 is a CEPT standard,
with a set value.
Unit Type
0
= Primary,
1
= Secondary
Table 6-5 E1 LP Parameters
Parameter
Valid Values
Default Value
LP Type
4
not valid here
Model Type
2
not valid here
Coding
3
3 (
HDB3
)
Framing
2
2 (
G.704
)
Line Service
0–1
0
Line Bui ld Out
6
6 (
G.703
)
Unit Type
0
0 (
Primary
)
Clocking
0–1
0
Expansion LP Attached
Y/N
N
LP “n”
Y/N
N
National Use Bit “n”
Y/N (
On/Off
)
N (
Off
)
CRC-4 Disabl ed?
Y/N
N
Internati onal Use bit
"n"
1
Y/N (
On/Off
)
N (
Off
)
Channel Signalling
0–1
0
X1,2,3 Bits
Y/N (
On/Off
)
N (
Off
)
A,B,C,D Bits
Y/N (
On/Off
)
N (
Off
)
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......