Alarms
21-25
b714
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPRSDM (Reset Slowdown Mode).
b715
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPSSDM (Set Slowdown Mode) and
the VC ID was invalid.
b716
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPRSET (Received SNRM for FRMR
reset by secondary; will send QSNRM to RSAP) the VC ID was
invalid.
b717
– during the link layer–to–PL message Main routine
(pl_lldata()) if the VC ID was invalid.
b718
– during the PL Main routine, the VC ID was invalid; this is
followed by another error containing the message VC ID.
ba01
– the link level data–to–level 3 routine (spfldtl3()) was called
and the data was lost.
ba02
– the Log Error Message routine (x_logerr()) was called from
the NPAD Finite State Machine module.
ba03
– the Trap Action routine (xllc_trap()) was called from the
NPAD Finite State Machine module.
bb01
– the spxllc_main() routine (called to receive all XPAD
messages) was called with an invalid port type.
bb02
– the spxllc_main() routine (called to receive all XPAD
messages) was called with a message type of NETFRM (received
frame from the driver) and the frame was more than the maximum
data size supported (12data_size).
bb03
– the spxllc_main() routine (called to receive all XPAD
messages) was called with an Unknown Message Type.
bb04
– the spll_ctlmsg() routine was called with an Unknown
Facility.
bb07
– the spll_pktmsg() routine (received message from the packet
layer) was called with an Unknown Facility.
bb08
– the spll_linkch() routine was called with an Unknown
Level 1 State.
bc01
– the SPLLC Main routine (spllcmr()) received a message with
a bad port type.
bd01
– the Acknowledge Queue exceeded the window. (Generated
from the Common Flow Chart Action routine of the SDLC
Secondary module (sps_ac91()).
bd02
– the Trap Action routine (sllc_trap()) of the SDLC Secondary
module was called.
be01
– the SDLC Main routine received a message of type
WACKOUT (no piggyback acknowledged)
be04
– the SNA exchange received an unknown message. This error
should be immediately followed by another event 147, containing
what is probably the correct error code.
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......