17
Specifications
Section 1-5
Automatic/Manual Mode (for each
task)
Automatic Mode: Mode for executing MC program created in G
language.
Manual Mode: Mode for executing manual commands from CPU
Unit (PLC interface area) or Teaching Box.
• The Automatic or Manual Mode is set according to the PLC
interface area of the CPU Unit.
• There are a total of 11 Automatic Mode commands, including
origin search, reference origin return, JOG, and error reset.
• The operation cycle is started in Automatic Mode through dedi-
cated bits in the CPU Unit or from the Teaching Box.
Encoder interface
Line receiver input; maximum response frequency: 500 kp/s
(before multiplication)
Pulse ratio: Select 1, 2, or 4
Note:
The applicable absolute encoders are the OMRON
OMNUC U-, W-, and G-series Encoders.
A Motion Control Unit with unit version 1.1 or later is
required to use the absolute encoder functionality of the
OMNUC G Series.
Control unit
Minimum setting
unit
1, 0.1, 0.01, 0.001, 0.0001
Units
mm, inch, degree, pulse (There is no unit conversion function.)
See note 3.
Maximum command value
–39,999,999 to +39,999,999
(When the minimum setting unit is 1.) (See note 6.)
Number of controlled axes
2 axes max.
4 axes max.
Positioning
operations
PTP (indepen-
dent) control
Execution by independent programs, operating modes for each
axis.
Linear interpola-
tion
2 axes max.
4 axes max.
Circular interpola-
tion
Circular interpolation for a maximum of two axes on a plane.
Helical circular
interpolation
---
Circular interpolation for a max-
imum of two axes on a plane +
one axis for feed control
Traverse function
Traverse operation for two axes
Speed control
Speed control for each axis
Unlimited Feed
Mode
Axis feeding can be executed with no limit.
Interrupt feeding
Feeding a fixed distance after an interrupt input, for each axis.
(Positioning with no interrupt input signals is also possible.)
Speed reference
1 pps to 2,000 kp/s (when ratio is 4)
Acceleration/deceleration curve
Trapezoidal or S-curve
Acceleration/deceleration time
Individual acceleration/deceleration settings possible: 0 to
100,000 ms (2-ms increments)
Item
Specifications
CS1W-MC221
CS1W-MC421
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...