611
System Parameters
Appendix D
17D7
(6103)
17D7
(6103)
W
Reading position
data
17D8
(6104)
17D8
(6104)
R/W
Specifying
automatic loading
17DE
(6110)
17DE
(6110)
W
Presetting the
X-axis present
position
17DF
(6111)
17DF
(6111)
W
Presetting the
Y-axis present
position
Sets the Y-axis present position to any value and checks the origin.
The data configuration is the same as that for presetting the X-axis
present position.
Address
R/W
Name
Description
MC221
MC421
L+0
L+1
L+2
L+3
L+4
L+5
15
12 11
08 07
04 03
00
0
0
0
0
0
0
0
0
Total number of words read
First source address for transferred position data
First destination word number for transferred position data
Transfer destination area designation (DM or EM)
This parameter can read a maximum of 2,000 positions from an MC Unit at
one time. It executes by specifying the address (17D7 Hex) with the first oper-
and of the IOWR instruction. Data is read to DM or EM.
Total number of words read
Specifies the total number of words for the 1 to 2,000 positions in multiples of
three since each position data item is formed from three words.
Range: 0003 to 1770 Hex (3 to 6,000, 3 words/data item)
First source address for transferred position data
Specifies the first source address number in MC Unit internal RAM for the
transferred position data.
Range: 0000 to 07CF Hex (0 to 1999)
First destination word number for transferred position data
Specifies the first word number of the DM or EM area that will store the trans-
ferred position data.
Transfer destination area designation
Specifies the DM or EM area for storing position data that will be transferred.
X = 0: DM area, X = 1 to D: Corresponds to banks 0 to C in the EM area
This parameter is used when batch downloading programs and posi-
tion data to an MC Unit from the external memory device of a person-
al computer with CX-Motion.
0
0
0
0
L+1
L
15
00 15
00
(Job number)
X (Job number)
Specifies a job number within a range from 0001 to 2710 Hex (1 to
10,000).
The following contents can be read this address using an IORD in-
struction.
X = 0000: Power supply ON, automatic loading completed normally
X = 0001 to 2710 Hex (1 to 10,000): Specified job number or execut-
ing job number
X
L+1
L
15
00 15
00
Preset value for the X-axis present position
Sets the X-axis present position to any value and checks the origin.
The data is 32-bit signed binary data.
L+1: Leftmost 16 bits, L: Rightmost 16 bits
Range: FD9DA601 to 026259FF Hex (
39999999 to 39999999)
The minimum setting unit is set to 2 (for 0.01), the display unit is set
to 0 (for mm) and the reference origin offset is 3.99 [mm] (i.e., 399
×
0.01) if the data is 399.
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...