624
Control Bit/Flag Timing Charts
Appendix E
35. Forced Block End Bit and Optional Input
When the Forced Block End Bit and the optional input are turned ON at the same time, the Forced Block End
Bit takes precedence, and the OPTIONAL SKIP command (G75) is forcibly stopped and becomes invalid.
When the program is restarted, the optional input is turned ON, but G01 is not skipped.
36. Forced Block End Bit and Optional Input
The OPTIONAL PROGRAM STOP command (G76) is cancelled by the Forced Block End Bit. The optional
input is turned OFF at the same time, but this is ignored and program execution is stopped.
37. Forced Block End Bit and Optional Input
The Forced Block End Bit takes precedence if it is turned ON at the same time as the optional input in the block
after an OPTIONAL END command (G74). The Unit stands by for restarting after program execution is
stopped.
Operation
Forced Block End Bit
Optional Input
Operation
Forced Block End Bit
Optional Input
Operation
Forced Block End Bit
Optional Input
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...