368
Electronic Gear Function
Section 6-18
When debugging, check the Error Flags from the ladder program.
Transfer Data (DM)
00000
OUT W00003
W00001
W00003
W00002
=
IOWR
#113A
D00100
#00020000
OUT W00005
W00001
W00005
W00004
=
MOVL
#00000001
D00100
IOWR
#113B
D00102
#00020000
MOVL
#0000000A
D00102
Execution condition
DIFU
W00001 (work bit)
This is the numerator address
(4410) for the X-axis SV1.
113A hex (4410)
Specifies the first source
word for the transfer data.
Specifies the destination unit
number (0) and the number of
words of data to be transferred (2).
OUT W00002 (work bit)
OUT W00004 (work bit)
SV1 numerator: 1
SV1 denominator: 10
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...