211
IOWR and IORD Specifications
Section 4-2
Example 1
Transferring Four Positions to A0456 to A0459 from D0100 to D0111
Ladder Program
Settings
DM Area
Note
Each position requires three words. Refer to
3-4 Position Data
for details.
Position data Position data address
A0456
A0457
A0458
A0459
345678.90
123456.78
−
387654.32
123.456
DIFU
R1
Work bit
IOWR
#01C8
D00100
#000C0000
R3
R2
R3
R1
R2
25506 (=)
Execution condition
Set position data
in DM Area as
shown below.
Set the first address of the MC Unit
position data to 0456 (01C8 Hex
corresponds to A0456).
Set the address of the first source word of
the position data.
Set the source unit number to 0 and a
total of 12 words to be transferred. (4
positions
×
3 words = 12 words)
OUT (Work bit)
OUT (Work bit)
0002
76D2
020F
0002
614E
00BC
0002
7C88
FDB0
0003
E240
0001
D0100
D0101
D0102
D0103
D0104
D0105
D0106
D0107
D0108
D0109
D0110
D0111
345678.90.
123456.78.
−
387654.32.
123.456.
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...