343
Operating Modes
Section 6-8
Constant Acceleration
Mode Limitations
The Constant Acceleration Mode can be used only for single-axis linear inter-
polation. When two or more axes are operated following a linear interpolation
operation in the Constant Acceleration Mode, the next operation will be exe-
cuted after positioning has been completed regardless of the operating mode
setting.
The following diagrams provide four examples of operations in the Constant
Acceleration Mode.
Example 1: Operation with One Axis Only
Operation is executed in
the specified mode (Stop
Mode, In-position Check
OFF Mode, or Pass
Mode) in this interval.
Example 2: Pass Operation with One Axis Only
Pass operation is executed and the Y axis is not oper-
ated even if it is specified. (In this case the amount of
relative movement is 0.)
Example 3: Operating from One Axis to Two Axes
Operation in
specified mode
X axis
Y axis
Example 4: Operating from One Axis to Two Axes
Operation in
specified mode
X axis
Y axis
G01 X100 F200
G01 X200 F400
N0000 P000 XY
N001 G91
N002 G01 X100 F200
N003 G01 Y0 F400F400
The Pass Mode is specified, but
the next operation is not executed
until it is determined that position-
ing has been completed. (The situ-
ation is the same with the In-
position Check OFF Mode.)
The Pass Mode is specified, but the
next operation is not executed until it
is determined that positioning has
been completed. (The situation is the
same with the In-position Check OFF
Mode.)
Operation in
Constant
Acceleration
Mode
N000 P000 XY
N001 G01 X100 F200
N002 G01 X200 Y300 X500 F300
N000 P000 XY
N001 G01 X100 Y100 F200
N002 G01 X300 F300
Operation in
Constant
Acceleration Mode
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...