502
System Configuration and Wiring
Section 11-2
Wiring the Input Unit
The following illustration shows an example of the switch box used as a test
device. Prepare the actual switch box and switches according to your system
specifications.
Switch Box Specifications
Connection Diagram
Switch Box
Operation
Start
Origin
Manual
Automatic
Switches between Manual and Automatic Mode (self-hold-
ing).
Push-button switch (self-resetting). When it is pressed in
Manual Mode, all axes are servo-locked.
Push-button switch (self-resetting). When it is pressed in
Automatic Mode, the MC program is executed.
Push-button switch (self-resetting). When it is pressed in
Manual Mode, the MC program is executed.
Push-button switches (self-resetting). When a switch is
pressed in Manual Mode, jogging is executed in either the
positive (CW) or negative (CCW) direction while the button
is being held down.
Switch Box
Manual
Automatic
Operation
Start
Origin
X+
X
−
Y+
Y
−
24 VDC
0
1
2
3
4
5
6
7
8
to
15
COM
C200H-
ID212
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...