93
Overview of Version 1 Upgrades
Section 1-12
Application
Precautions
• After areas have been enabled using the IOWR instruction (control data =
1838, 183A, 183C, 183E), 0 will be output for the next I/O refresh and the
position data will be output from the following I/O refresh. If the time from
executing IOWR to the first I/O refresh is less than 10 ms, one more cycle
time may be required.
• After words have been enabled using the IOWR instruction (control data =
1838 to 183F) or after changing the word allocations when other words
were previously enabled, the present values will remain in the words that
were previously refreshed.
• When enabled output data areas (A1970 to A1971, A1974 to A1975,
A1978 to A1979, A1982 to A1983) and word data being refreshed in the
CPU Unit are overwritten, the data will be refreshed during the next I/O
refresh period.
• When enabled input data areas (A1972 to A1973, A1976 to A1977,
A1980 to A1981, A1984 to A1985) are overwritten, the contents of the
CPU Unit data words will remain unchanged until the next I/O refresh
period.
• Refreshing will continue even when loads (outputs) are turned OFF by the
CPU Unit.
• Complete setting A1986 to A1989 at least 10 ms before the output for the
stopover function. If the output occurs in less than 10 ms, operation will be
performed with the previous values of A1986 to A1989.
1-12-1-8
Resetting M Codes with Program Execution Stopped
Overview
If this function is enabled, the M Code Reset Bit allocated in the CPU Unit can
be used to reset the M code from the CPU Unit even when program execution
is stopped.
Specifications
Settings
There are no settings required for this function. This function is enabled as
soon as the IOWR instruction is executed to select the customized function.
The following tables show when the M Code Reset Bit is valid.
Function Enabled
During program execution
(Except during
decelerations for pausing
operation)
All other times
When outputting
M000 to M499
Valid
Valid
(Except during decelerations
for pausing operation)
Note
M code reset standby
status will not be
entered when program
execution is restarted.
When outputting
M500 to M999
Valid
Valid
Summary of Contents for CS1W-MC221 -
Page 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Page 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 11: ...xii ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Page 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Page 227: ...200 Command Area Section 3 6 ...
Page 351: ...324 Interface Specifics Section 5 4 ...
Page 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Page 575: ...548 Error Log Section 12 6 ...
Page 589: ...562 Performance Appendix A ...
Page 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Page 683: ...656 Origin Search Patterns Appendix F ...
Page 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...