Rev. 1.0, 02/00, page 285 of 1141
14.2.4
Module Stop Control Register (MSTPCR)
7
1
MSTP15
R/W
MSTPCRH
6
1
MSTP14
R/W
5
1
MSTP13
R/W
4
1
MSTP12
R/W
3
1
MSTP11
R/W
2
1
MSTP10
R/W
1
1
MSTP9
R/W
0
1
MSTP8
R/W
7
1
MSTP7
R/W
6
1
MSTP6
R/W
5
1
MSTP5
R/W
4
1
MSTP4
R/W
3
1
MSTP3
R/W
2
1
MSTP2
R/W
1
1
MSTP1
R/W
0
1
MSTP0
R/W
MSTPCRL
Bit :
Initial value :
R/W :
The MSTPCR are 8-bit read/write twin registers which work to control the module stop mode.
When the MSTP12 bit is set to 1, timer L stops its operation at the ending point of the bus cycle to
shift to the module stop mode. For more information, see section 4.5, Module Stop Mode.
When reset, the MSTPCR is initialized to H'FFFF.
Bit 4
Module Stop (MSTP12): This bit works to designate the module stop mode for timer L.
MSTPCRH
Bit 4
MSTP12
Description
0
Cancels the module stop mode of timer L
1
Sets the module stop mode of timer L
(Initial value)