Rev. 1.0, 02/00, page 284 of 1141
14.2.2
Linear Time Counter (LTC)
0
0
1
0
R
2
0
3
0
4
5
6
0
7
R
R
R
R
LTC6
0
R
LTC5
0
R
LTC4
0
R
LTC7
LTC3
LTC2
LTC1
LTC0
Bit :
Initial value :
R/W :
The linear time counter (LTC) is a readable 8-bit up/down-counter. The inputting clock can be
selected by the LMR2 to LMR0 bits of the LMR.
When reset, the LTC is initialized to H'00.
14.2.3
Reload/Compare Match Register (RCR)
0
0
1
0
W
2
0
3
0
4
5
6
0
7
W
W
W
W
RCR6
0
W
RCR5
0
W
RCR4
0
W
RCR7
RCR3
RCR2
RCR1
RCR0
Bit :
Initial value :
R/W :
The reload/compare match register (RCR) is an 8-bit write only register.
When timer L is being controlled to the up-counting function, when a compare match value is set
to the RCR, the LTC will be cleared at the same time and the LTC will then start counting up from
the initial value (H'00).
While, when the Timer L is being controlled to the down-counting function, when a reloading
value is set to the RCR, the same value will be loaded to the LTC at the same time and the LTC
will then start counting up from said value. Also, when the LTC underflows, the value of the RCR
will be reloaded to the LTC.