Mixed signal option (MSO, R&S
RTO6-B1)
R&S
®
RTO6
1002
User Manual 1801.6687.02 ─ 05
"Stays high"
The level of a digital channel stays above the threshold, or the logical
expression for "Logic" trigger source is true.
"Stays low"
The level of a digital channel stays below the threshold, or the logical
expression for "Logic" trigger source is false.
"High or low"
The signal state remains unchanged.
Remote command:
TRIGger<m>:PARallel:TIMeout:RANGe
Time
Defines the time limit for the timeout at which the instrument triggers.
Remote command:
TRIGger<m>:PARallel:TIMeout:TIME
Logical expression
Defines a logic combination of several digital channels as trigger condition if "Logic" is
set for "Source". The "Qualification Editor" supports the entry of the expression.
Remote command:
TRIGger<m>:PARallel:TIMeout:EXPRession[:DEFine]
TRIGger<m>:PARallel:STATe:EXPRession[:DEFine]
TRIGger<m>:PARallel:PATTern:EXPRession[:DEFine]
TRIGger<m>:PARallel:SPATtern:EXPRession[:DEFine]
14.3.1.5
Setup & Hold
The Setup & Hold trigger event occurs when the state of the trigger source signal
changes inside a given time before the clock edge (setup time) or after the clock edge
(hold time). The trigger event occurs at the clock edge for which the setup and/or hold
time was violated.
With Setup & Hold trigger, you can trigger on a single digital channel, or a parallel bus
to check several digital channels simultaneously. The clock signal is connected to one
of the digital channels.
If you configure this trigger type for a parallel bus, the bus configuration is adjusted by
the instrument if necessary. The bus is defined as clocked bus, and the clock source of
the trigger is set as clock source of the bus.
Trigger