Remote control commands
R&S
®
RTO6
1610
User Manual 1801.6687.02 ─ 05
24.15.5
Interval search conditions
Trigger level setting:
.................................................................................1610
..................................................................................1610
................................................................................1610
................................................................................. 1611
SEARch:TRIGger:INTerval:SLOPe
<SearchName>,<Slope>
SEARch:TRIGger:INTerval:SLOPe?
<SearchName>
Sets the edge for the search.
Parameters:
<Slope>
POSitive | NEGative | EITHer
See
Chapter 24.4.3, "Slope parameter"
*RST:
POSitive
Parameters for setting and query:
<SearchName>
String parameter, name of the search definition
Usage:
Asynchronous command
SEARch:TRIGger:INTerval:DELTa
<SearchName>,<WidthDelta>
SEARch:TRIGger:INTerval:DELTa?
<SearchName>
Defines a range around the "Interval width" value (see
Parameters:
<WidthDelta>
Range:
0 to 10
Increment: 100E-9
*RST:
0
Default unit: s
Parameters for setting and query:
<SearchName>
Search definition
Usage:
Asynchronous command
SEARch:TRIGger:INTerval:RANGe
<SearchName>,<RangeMode>
SEARch:TRIGger:INTerval:RANGe?
<SearchName>
Selects how the range of an interval is defined based on the interval width and delta
(see
on page 1611 and
Parameters:
<RangeMode>
WITHin | OUTSide | SHORter | LONGer
Search