![R&S RTO6 User Manual Download Page 837](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_3064646837.webp)
Protocol analysis
R&S
®
RTO6
837
User Manual 1801.6687.02 ─ 05
"Condition"
Defining a specific endpoint or an endpoint range requires to set the
operator to one of the following: equal, not equal, less than, less than
or equal, greater than, greater than or equal, in range, out of range.
"Min"
Specifies an endpoint, or sets the start value of an endpoint range.
"Max"
Sets the end value of an endpoint range if "Condition" (
INRange
or
OORange
.
Remote command:
Frame number check
Enables the search for a frame number that meets specific conditions.
"Condition"
Defining a specific frame number or a frame number range requires
to set the operator to one of the following: equal, not equal, less than,
less than or equal, greater than, greater than or equal, in range, out
of range.
"Min"
Specifies a frame number, or sets the start value of a frame number
range.
"Max"
Sets the end value of a frame number range if "Condition" (
INRange
or
OORange
.
Remote command:
Payload check
Enables the search for a payload data pattern that meets specific conditions.
"Condition"
Sets the operator "any" or "equal" that allows to search for payload
data at any position or at a specified position.
"Position"
Available only if "Condition" (
)
is set to
equal
. Specifies the position in which a special data pattern
is to be searched within the payload data packet.
"Data Condi-
tion"
Sets the operator ("equal" or "unequal",
) to set a specific payload data pattern.
"Payload pat-
tern"
Specifies the payload data pattern that is to be searched.
Remote command:
USB (option R&S
RTO6-K570)