Network operation and remote control
R&S
®
RTO6
1247
User Manual 1801.6687.02 ─ 05
Table 22-2: Bits in the STATus:OPERation register
Bit No.
Meaning
0
ALIGnment
This bit is set as long as the instrument is performing a self-alignment.
1
Not used
2
AUToset
This bit is set while the instrument is performing an auto setup.
3
WTRIgger
The wait for trigger status bit indicates that the instrument is ready to trigger, and the pre-trigger
time is expired. The bit is set if the instrument did not trigger for more than 10 ms.
The bit is only valid if the trigger event is initiated by the user, for example, using an external
generator. If the instrument triggers on signals or if it is in auto trigger mode, the bit status is
undefined.
4
MEASuring
The bit is set as long as an acquisition - sampling and postprocessing - is running. In run contin-
uous mode, the bit is always set.
5 - 15
Not used
STATus:QUEStionable register
This register contains information about indefinite states which may occur if the unit is
operated without meeting the specifications. It can be read using the commands
STATus:QUEStionable:CONDition?
and
STATus:QUEStionable[:EVENt]?
The remote commands for the STATus:QUEStionable register are described in
ter 24.26.2, "STATus:QUEStionable registers"
Remote control