Remote control commands
R&S
®
RTO6
1431
User Manual 1801.6687.02 ─ 05
TRIGger<m>:OUT:PLENgth
<PulseLength>
Sets the length of the trigger out pulse.
Suffix:
<m>
.
1..3
Irrelevant, omit the suffix.
Parameters:
<PulseLength>
Range:
4E-9 to 0.06
Increment: 20E-9
*RST:
100E-9
Default unit: s
Usage:
Asynchronous command
TRIGger<m>:OUT:DELay
<Delay>
Sets the delay of the first pulse edge to the trigger point.
The setting is not available if a mask test or measurement is running and the on-viola-
tion event is set to trigger out pulse.
Suffix:
<m>
.
1..3
Irrelevant, omit the suffix.
Parameters:
<Delay>
Range:
800E-9 to 1
Increment: 1E-9
*RST:
800E-9
Default unit: s
Usage:
Asynchronous command
24.9.20
Actions on trigger
........................................................................................... 1431
........................................................................................... 1432
.....................................................................................1432
...................................................................................... 1432
............................................................................................ 1433
TRIGger<m>:EVENt:BEEP
<Beep>
Generates a beep sound if the command is set to
TRIGger
.
Suffix:
<m>
.
1..3
The suffix is irrelevant.
Trigger