Remote control commands
R&S
®
RTO6
1937
User Manual 1801.6687.02 ─ 05
TRIGger<m>:CXPI:DLC:CONDition
<DLCOperator>
Set the condition for the DLC. You can define an exact value or a value range.
Suffix:
<m>
.
1..3
Parameters:
<DLCOperator>
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one DLC pattern
to be set with the corresponding
command.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with
and
*RST:
EQUal
TRIGger<m>:CXPI:DLC:MAX
<DLCMax>
Sets the end value of a data type range if
to
INRange
or
OORange
.
Suffix:
<m>
.
1..3
Parameters:
<DLCMax>
TRIGger<m>:CXPI:DLC:MIN
<DLCMin>
Specifies a DLC pattern, or sets the start value of a pattern range.
Suffix:
<m>
.
1..3
Parameters:
<DLCMin>
TRIGger<m>:CXPI:ERRor:CRC
<ErrorCRC>
Triggers on a cyclic redundancy check error, if
ERRor
.
The transmitting node calculates the cyclic redundancy check (CRC) value of a frame
and stores it into the CRC field of the frame. CRC error occurs when this CRC field
value differs from the value calculated by the receiving node.