Sets the trigger to a combination of identifier and data condition. The
instrument triggers at the end of the last byte of the specified data
pattern.
The identifier conditions are the same as for the "Identifier" trigger
type, see
"Identifier setup: Condition, Identifier min, Identifier max"
on page 590. Data conditions are set with
Transfer, Condition, Data min, Data max"
"Error condi-
tion"
Identifies various errors in the frame, see
CAN and CAN FD (option R&S
RTO6-K520)