Protocol analysis
R&S
®
RTO6
770
User Manual 1801.6687.02 ─ 05
Decode Results Table
The results are shown in two tables:
●
"Decode results": contains information about all decoded frames
●
"Details frame": contains more detailed information about the selected frame in the
"Decode results" table.
Table 13-26: Content of the Decode results table
Column
Description
State
Overall state of the frame.
"Insuffcient waveform length" indicates that the frame is not completely contained
in the acquisition. Change the horizontal scale, or move the reference point to the
left to get a longer acquisition.
Start
Time of command sequence start (SSC)
Type
Type of the command sequence
SA /MID
Address of the SA/ MID
BC
Byte count (decimal value)
Address
Register address (hex value)
Label
Symbolic name of the address if a label list is applied.
Table 13-27: Content of the Details frame table
Column
Description
Parity control
Checks if there an error in the parity
Parity address 0/1
Checks if there an error in the parity address
Read bit rate
Value of the read bit rate
Write bit rate
Value of the write bit rate
Name
Type of the command sequence
State
Overall state of the frame.
"Insuffcient waveform length" indicates that the frame is not completely contained
in the acquisition. Change the horizontal scale, or move the reference point to the
left to get a longer acquisition.
Value
Values of the data bytes.
Tools
Press "Display settings" in the "Decode Results" table to access the "Display" tab.
RFFE (option R&S
RTO6-K550)