![R&S RTO6 User Manual Download Page 1264](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461264.webp)
Remote control commands
R&S
®
RTO6
1264
User Manual 1801.6687.02 ─ 05
*OPC?
MEAS1:RES:ACT?
MEAS2:RES:ACT?
Exporting histogram data to file
The example writes the absolute data values of Histogram1 to
C:\Histograms\Hist1.xml
in XML format.
Command description in
Chapter 24.16.5, "Waveform histogram export to file"
EXPort:HISTogram:SELect 'Histogram1'
EXPort:HISTogram:INCidence ABS
EXPort:HISTogram:NAME 'C:\Histograms\Hist1.xml'
EXPort:HISTogram:SAVE
*OPC?
Transferring histogram data
The example transfers the absolute values of Histogram1 to a controlling computer in
ASCII format.
Command description in
Chapter 24.16.5, "Waveform histogram export to file"
EXP:HIST:SEL 'Histogram1'
EXP:HIST:INC ABS
*OPC?
FORM ASC
EXP:HIST:DATA?
<--0,0,0,0,0,2037,5754804,4683496,3100169,2874565,...
24.3.2.4
Long-term measurements
In the following example
*OPC
prevents overlapping execution of asynchronous com-
mands.
Exporting long-term measurement data to file
.................................................... 1264
Transferring long-term measurement data
..........................................................1265
Exporting long-term measurement data to file
The example writes the long-term data of Meas1 to
C:\Measurements\Meas1.csv
in CSV format.
Command description in
Chapter 24.16.7, "Long term measurement results and mea-
surement histogram export to file"
EXPort:MEASurement:SEL MEAS1
EXPort:MEASurement:TYPE LONGTERM
EXPort:MEASurement:NAME 'C:\Measurements\Meas1.csv'
Programming examples