Triggers
R&S
®
RTO6
197
User Manual 1801.6687.02 ─ 05
Remote command:
6.3.3
Glitch
Access: "Menu" > "Trigger" > "Setup" tab > "Type = Glitch"
The glitch trigger detects pulses shorter or longer than a specified time. It identifies
deviation from the nominal data rate and helps to analyze causes of even rare glitches
and their effects on other signals.
Polarity
Indicates the polarity of a pulse, that is the direction of the first pulse slope.
"Positive"
Selects positive going pulses.
"Negative"
Selects negative going pulses.
"Either"
Selects both positive and negative going pulses.
Remote command:
Range
Selects which glitches are identified: shorter or longer than the specified "Width".
Remote command:
Width
Sets the length of a glitch. The instrument triggers on pulses shorter or longer than this
value. The minimum width is 100 ps.
You need to know the expected pulse widths of the circuit to set the glitch width cor-
rectly.
Trigger types