![R&S RTO6 User Manual Download Page 1913](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461913.webp)
Remote control commands
R&S
®
RTO6
1913
User Manual 1801.6687.02 ─ 05
Return values:
<State>
OK | UNDF
UNDF: Undefined
*RST:
OK
Usage:
Query only
BUS<m>:SENT:FRAMe<n>:NIBBle<o>:VALue?
Returns the value of the specified nibble.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n>
*
Selects the frame.
<o>
*
Selects the nibble number.
Return values:
<Value>
.
The values below
–
range, increment and reset
–
are decimal
values.
Range:
0 to 15
Increment: 1
*RST:
0
Usage:
Query only
BUS<m>:SENT:FRAMe<n>:PAPTicks?
Returns the number of the pulse pause clock ticks.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n>
*
Selects the frame.
Return values:
<PausePulseTicks>
Range:
12 to 768
Increment: 1
*RST:
12
Usage:
Query only
BUS<m>:SENT:FRAMe<n>:SCOM?
Returns the value of the status/communication pulse.
Protocols