Remote control commands
R&S
®
RTO6
1847
User Manual 1801.6687.02 ─ 05
Usage:
Query only
BUS<m>:LIN:FRAMe<n>:SDATa?
Returns the complete symbolic data of the frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n>
*
Selects the frame.
Return values:
<SymbolicData>
Usage:
Query only
BUS<m>:LIN:FRAMe<n>:SDEXport?
Returns the symbolic data of the frame in export format.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n>
*
Selects the frame.
Return values:
<SymbolicData>
Usage:
Query only
BUS<m>:LIN:FRAMe<n>:SYMBol?
Returns the symbolic label of the specified frame if the label list is enabled.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n>
*
Selects the number of the frame in the current acquisition, 1...n.
Return values:
<Label>
String with symbolic name of the identifier
Example:
BUS:LIN:FRAMe2:SYMBol?
Response:
Temperature
Usage: