Protocol analysis
R&S
®
RTO6
576
User Manual 1801.6687.02 ─ 05
Table 13-9: Content of the "Decode results details" table
Column
Description
State
Overall state of the cell: either OK or the relevant error condition (e.g. length error)
Type
The type of frame, as specified with the "Frame type"
Numeric
Data content of the cell (e.g. 0x1, 1000LL00L)
Tools
Press "Display settings" in the "Decode Results" table to access the "Display" tab.
Remote commands
Remote commands are described in
Chapter 24.17.7.4, "Decode results"
13.6.6
Search on decoded custom Manchester / NRZ data
Using the search functionality, you can find various events in the decoded data. You
can find the same events that you can trigger on, and even many more, since several
event types can also be combined.
Before you can start the search, you have to configure the bus correctly and acquire
decoded data.
To search on decoded data, set the search source to "SerBus" for the configured proto-
col.
For general information on how to handle the search functionality, see
If you need information on how to get started with searching custom serial bus data,
see
Chapter 13.6.6.3, "Searching custom serial bus data"
proceed with the custom serial bus search setup.
13.6.6.1
Custom Manchester / NRZ search setup
Access: [Bus] > "Shortcuts" tab > "Setup search"
Search criteria
Use the "Search criteria" dialog to define the event types to be searched. Available
event types are "Frame" and "Error".
Individual search parameters, which do not depend on the coding standard and trigger
settings of the custom serial bus, can be specified in the tabs below the "Search crite-
ria" dialog.
Frame
Searches for four different frame conditions.
Custom: Manchester / NRZ (option R&S
RTO6-K510)