![R&S RTO6 User Manual Download Page 771](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_3064646771.webp)
Protocol analysis
R&S
®
RTO6
771
User Manual 1801.6687.02 ─ 05
Remote commands
Remote commands to retrieve decode results are described in
13.17.6
Search on decoded RFFE data
Using the search functionality, you can find various events in the decoded data, the
same events which you also can trigger on. Before you can start the search, you have
to configure the bus correctly and acquire decoded data.
To search on decoded data, set the search "Source" to the serial bus that is configured
for the protocol to be analyzed.
See also
Chapter 11, "Search functions"
13.17.6.1
RFFE search setup
Access: [Bus] > "Shortcuts" tab > "Setup search"
Type
The search criterion is defined by "Type". All trigger types are also available for search.
Additional search parameters are provided under "Detailed Search Parameter Setup".
For details, see also
"Sequence Start"
Searches for SSC.
Additional search parameter:
"Sequence Stop"
Searches for bus park at the end of a command sequence.
Additional search parameter:
RFFE (option R&S
RTO6-K550)