Remote control commands
R&S
®
RTO6
2224
User Manual 1801.6687.02 ─ 05
OFF
Checking condition disabled
*RST:
OFF
Example:
TRIGger:USBPd:FRAMe3:FLD1:ENABle ON
Enables the checking condition for the Extended field of the
Control frame.
TRIGger:USBPd:FRENable "Data Frame", "Data
Role" ON
Enables the checking condition for the Data Role field of the
Data frame.
TRIGger<m>:USBPd:BIT
<Frame>, <Field>, <Bit>
TRIGger<m>:USBPd:FRAMe<n>:FLD<o>:BIT
<BitState>
Sets the bit state of a field that only consists of one bit.
Suffix:
<m>
.
1..3
<n>
*
<o>
*
Specifies the field number within the frame.
Parameters:
<BitState>
ONE | ZERO | DC
ONE
1
ZERO
0
DC
"Don't care" (DC) = X
*RST:
DC
TRIGger<m>:USBPd:DMAX
<Frame>, <Field>, <Data>
TRIGger<m>:USBPd:FRAMe<n>:FLD<o>:DMAX
<DataMax>
Sets the end value of a data pattern range if
is set to
INRange
or
OORange
.
Suffix:
<m>
.
1..3
<n>
*
Specifies the field number within the frame.
<o>
*
Parameters:
<DataMax>
Specifies the name of the generic trigger setting frame, see
BUS<m>:USBPd:RESult:FRAMe<n>:TYPE?
Protocols