![R&S RTO6 User Manual Download Page 1910](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461910.webp)
Remote control commands
R&S
®
RTO6
1910
User Manual 1801.6687.02 ─ 05
Suffix:
<m>
.
1..4
Selects the serial data bus.
Return values:
<Count>
Total number of decoded frames.
Range:
0 to 100000
Increment: 1
*RST:
0
Usage:
Query only
BUS<m>:SENT:FRAMe<n>:STATus?
Returns the overall state of the selected frame.
Suffix:
<m>
.
1..4
Selects the serial data bus.
<n>
*
Selects the frame.
Return values:
<FrameState>
OK | SYNC | PULSe | CRC | IRFL | FORM | INSufficient
OK: the frame is valid.
SYNC: Synchronization error occurred.
PULse: Pulse error occurred.
CRC: Cyclic redundancy check failed.
IRFL: Irregular frame length error occurred.
FORM: Format error occurred.
INSufficient: The frame is not completely contained in the acqui-
sition. The acquired part of the frame is valid.
*RST:
OK
Usage:
Query only
BUS<m>:SENT:FRAMe<n>:STARt?
BUS<m>:SENT:FRAMe<n>:STOP?
Returns the start time and stop time of the selected frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n>
*
Selects the frame.
Protocols