POWer:SPECtrum:REPort:ADD
Adds the result to the report list.
Usage:
Event
POWer:SPECtrum:RCOunt?
Returns the total number of harmonics.
Return values:
<ResultCount>
Usage:
Query only
POWer:SPECtrum:RESult<m>:FREQuency?
Returns the result frequency of the m-th result value.
Suffix:
<m>
.
1..*
Return values:
<Frequency>
Usage:
Query only
POWer:SPECtrum:RESult<m>:LEVel?
Returns the result level of the m-th result value.
Suffix:
<m>
.
1..*
Return values:
<Level>
Usage:
Query only
24.24
Deembedding (option R&S
RTO6-K121)
Some of the commands in the following chapter are asynchronous. An overlapping or
asynchronous command does not automatically finish executing before the next com-
mand starts executing. If overlapping commands must be executed in a defined order,
e.g. to avoid wrong measurement results, they must be serviced sequentially.
To prevent an overlapping execution of commands, one of the commands
*OPC
,
*OPC?
or
*WAI
can be used after the command or a command set.
For more information, see:
●
www.rohde-schwarz.com/rc-via-scpi
, chapter "Command Sequence and Synchro-
nization"
Deembedding (option R&S