Remote control commands
R&S
®
RTO6
2014
User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:SWIRe:TYPE
<SearchName>,<Type>
SEARch:TRIGger:SWIRe:TYPE?
<SearchName>
Sets the search type for the SpaceWire analysis.
Parameters:
<Type>
CTRL | DATA | NULL | TIME | ERRor
*RST:
CTRL
Parameters for setting and query:
<SearchName>
24.17.15.5
Search results
In all
SEARch:RESult:DPHY:FRAMe<m>
commands, the suffix <m> selects the frame
number in the list of search results.
..................................................................................2014
SEARch:RESult:SWIRe:FRAMe<m>:DATA?
...................................................................2014
SEARch:RESult:SWIRe:FRAMe<m>:STARt?
..................................................................2015
SEARch:RESult:SWIRe:FRAMe<m>:STATe?
..................................................................2015
SEARch:RESult:SWIRe:FRAMe<m>:STOP?
.................................................................. 2015
SEARch:RESult:SWIRe:FRAMe<m>:TYPE?
.................................................................. 2016
SEARch:RESult:SWIRe:FCOunt?
<SearchName>
Returns the number of frames within the search result for the selected serial bus.
Query parameters:
<SearchName>
Return values:
<FrameCount>
Range:
0 to 100000
Increment: 1
*RST:
0
Usage:
Query only
SEARch:RESult:SWIRe:FRAMe<m>:DATA?
<SearchName>
Returns the data value for the selected frame within the search result.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<Data>
Usage:
Query only
Protocols