Remote control commands
R&S
®
RTO6
2405
User Manual 1801.6687.02 ─ 05
Parameters:
<PositionUI>
Range:
-100E+9 to 100E+9
Increment: 0.01
*RST:
0.5
Default unit: UI
Usage:
Asynchronous command
EYE<m>:TIMReference:CLOCk:EDGE
<EdgeType>
The clock edge sets the point in time when the state of the data signal is checked.
Suffix:
<m>
.
1..4
Parameters:
<EdgeType>
POSitive | NEGative | EITHer
*RST:
EITHer
Usage:
Asynchronous command
EYE<m>:TIMReference:CLOCk:FACTor
<Factor>
Sets a clock multiplier factor.
Available if
CLOCk
.
Suffix:
<m>
.
1..4
Parameters:
<Factor>
Range:
1 to 100
Increment: 1
*RST:
1
Usage:
Asynchronous command
EYE<m>:TIMReference:CLOCk:FREQuency
<Frequency>
Sets the clock frequency for the explicit clock signal.
Available if
CLOCk
.
Suffix:
<m>
.
1..4
Parameters:
<Frequency>
Range:
1000 to 10E+9
Increment: 10
*RST:
1E+9
Default unit: Hz
Usage:
Asynchronous command