Protocol analysis
R&S
®
RTO6
855
User Manual 1801.6687.02 ─ 05
Field name / Condition Summary / Enable ← Set details
This table lists the field numbers and names in the selected frame together with a sum-
mary of the user settings of checking conditions for each field and a checkbox to
enable the checking.
It also shows the user settings of checking conditions for each field and a checkbox to
enable the checking.
Select a field in the table to specify the checking conditions for this field in the "Set
details" dialog.
For an overview of frames and fields, see
Remote command:
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:ENABle
Data
Defines for the selected field, how a data check is executed.
"Condition"
Sets the comparison condition to a specific value or a range.
"Min"
Specifies the value or sets the start value of a range.
"Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:DOPerator
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:DMIN
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:DMAX
USB 3.1 (option R&S
RTO6-K570)