Remote control commands
R&S
®
RTO6
1419
User Manual 1801.6687.02 ─ 05
●
D[:ENABle]: C4
The trigger source cannot be enabled.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n>
1..18
Trigger type, see
.
Parameters:
<State>
ON | OFF
ON
The qualification expression is considered.
OFF
The qualification expression is ignored.
*RST:
OFF
Usage:
Asynchronous command
TRIGger<m>:QUALify<n>:A:LOGic
<Operator>
TRIGger<m>:QUALify<n>:B:LOGic
<Operator>
TRIGger<m>:QUALify<n>:C:LOGic
<Operator>
TRIGger<m>:QUALify<n>:D:LOGic
<Operator>
Defines the logic for the indicated channel:
●
A: C1
●
B: C2
●
C: C3
●
D: C4
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n>
1..18
Trigger type, see
.
Parameters:
<Operator>
DIRect | HIGH | NOT | LOW
DIRect
Input value remains unchanged
NOT
Input value is inverted
*RST:
DIRect
Usage:
Asynchronous command
Trigger