Remote control commands
R&S
®
RTO6
1874
User Manual 1801.6687.02 ─ 05
*RST:
OFF
TRIGger<m>:FLXRay:PMIN
<PayloadLength>
Specifies a payload length - the number of words in the payload segment - or sets the
the start value of an payload length range. Information is transmitted in 2-byte words,
so the number of data bytes in the payload segment is twice the payload length.
Parameters:
<PayloadLength>
Range:
0 to 127
Increment: 1
*RST:
0
TRIGger<m>:FLXRay:PMAX
<PayloadLengthTo>
Sets the the end value of a payload length range if the condition
is set to
INRange
or
OORange
.
Parameters:
<PayloadLengthTo> Range:
0 to 127
Increment: 1
*RST:
0
TRIGger<m>:FLXRay:CENable
<CycleCount>
Sets the operator to define a cycle count or a cycle count range.
Parameters:
<CycleCount>
OFF | EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
OFF
The cycle count is not relevant for the trigger condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one cycle count
number to be set with
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with
and
*RST:
OFF
TRIGger<m>:FLXRay:CMIN
<CycleCountMin>
Specifies a cycle count - the number of the current FlexRay cycle - or sets the the start
value of an cycle count range.
Protocols