EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one frame ID to
be set with
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with
and
*RST:
EQUal
TRIGger<m>:FLXRay:FMIN
<IdPattern>
Specifies a frame identifier pattern - the number of the slot - or sets the the start value
of an identifier range.
Parameters:
IdPattern
Numeric or string pattern, see
TRIGger<m>:FLXRay:FMAX
<IdPatternTo>
Sets the the end value of an identifier range if the condition
is set to
INRange
or
OORange
.
Parameters:
IdPatternTo
Numeric or string pattern, see
FMAX must be greater or equal than FMIN, and the position of
the X bits are common to FMIN and FMAX.
TRIGger<m>:FLXRay:PCONdition
<PayloadLengthOp>
Sets the operator for the payload length trigger setting. You can defined an exact
value, or a range.
Parameters:
<PayloadLengthOp> OFF | ANY | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
OFF = ANY
The payload length is not relevant for the trigger condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one payload
length to be set with
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with
and