Remote control commands
R&S
®
RTO6
1871
User Manual 1801.6687.02 ─ 05
TRIGger<m>:FLXRay:TYPE
<Type>
Selects the trigger type for FlexRay analysis.
Parameters:
<Type>
STOF | IDDT | SYMBol | ERRC
STOF
STart Of Frame: triggers on the first rising edge after the trans-
mission start sequence (TSS).
IDDT
IDentifier and DaTa: triggers on the decoded frame content, on
header and payload data.
For all settings that are not needed for the trigger condition,
make sure to set its condition to
OFF
.
Indicator bits
: see
Frame identifier
: sets the trigger to one specific frame ID or an
identifier range. To set the identifier, use
, and
Payload length
: trigger on the number of words in the payload
segment. To set the payload length, use
, and
Cycle count
: trigger on the number of the current FlexRay cycle.
To set the cycle count, use
,
.
Data position
: sets the position of the data bit pattern within the
payload segment. To set the data position, use
,
.
Data bit pattern
: sets the data bit pattern to be found in the pay-
load segment. The starting point of the pattern is defined by the
data position. To set the bit pattern, use
, and
SYMBol
Triggers on a symbol or wakeup pattern. Set the required sym-
bol with
ERRC
ERRor Condition: triggers on one or more errors that are detec-
ted in the decoded data. Use
,
*RST:
STOF
Protocols