Remote control commands
R&S
®
RTO6
1797
User Manual 1801.6687.02 ─ 05
Alternatively, you can set the threshold according to the signal technology with
.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Threshold>
Range:
-12 to 12
Increment: 0.1
*RST:
0
Default unit: V
BUS<m>:CAN:TECHnology
<Technology>
Sets the threshold voltage as defined for various signal technologies.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Technology>
V25 | V3 | V2 | V0 | MANual
V25
2.5 Volt (CMOS 5.0 V)
V3
3.0 Volt (CAN_H HS / CAN_L LS)
V2
2.0 Volt (CAN_L HS / CAN_H LS)
V0
Ground
MANual
Manual setting of user-defined values with
*RST:
V25
BUS<m>:CAN:BITRate
<Bitrate>
For CAN buses, the "Bit rate" sets the number of transmitted bits per second.
For CAN FD buses, this parameter is called "Arbitration rate" and sets the bit rate of
the arbitration phase.
The maximum bit rate for High Speed CAN is 1
Mbit/s. The bit rate is uniform and fixed
for a given CAN or CAN FD bus.
Suffix:
<m>
.
1..4
Selects the serial bus.
Protocols