![R&S RTO6 User Manual Download Page 2545](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646462545.webp)
Remote control commands
R&S
®
RTO6
2545
User Manual 1801.6687.02 ─ 05
POWer:SWITching:SWIT
<MeasSwitchingFreq>
Activates or deactivates the measurements of the switching frequency.
Parameters:
<MeasSwitchingFreq>ON | OFF
*RST:
ON
POWer:SWITching:COND
<MeasureConduction>
POWer:SWITching:NCON
<MeasureNonConduction>
POWer:SWITching:TON
<MeasureTurnOn>
POWer:SWITching:TOFF
<MeasureTurnOff>
POWer:SWITching:TOTal
<MeasureTotal>
Enables the measurement during the respective period.
Parameters:
<MeasureTotal>
ON | OFF
*RST:
ON
POWer:SWITching:GATE:COND:STARt
<T1>
POWer:SWITching:GATE:COND:STOP
<T2>
POWer:SWITching:GATE:NCON:STARt
<T3>
POWer:SWITching:GATE:TOFF:STARt
<T2>
POWer:SWITching:GATE:TOFF:STOP
<T3>
POWer:SWITching:GATE:TON:STARt
<T0>
POWer:SWITching:GATE:TON:STOP
<T1>
Sets the value for the respective cursor.
Parameters:
<T1>
POWer:SWITching:RESult:ENERgy:ACTual?
<MeasType>
POWer:SWITching:RESult:ENERgy:AVG?
<MeasType>
POWer:SWITching:RESult:ENERgy:EVTCount?
<MeasType>
POWer:SWITching:RESult:ENERgy:NPEak?
<MeasType>
POWer:SWITching:RESult:ENERgy:PPEak?
<MeasType>
POWer:SWITching:RESult:ENERgy:RMS?
<MeasType>
POWer:SWITching:RESult:ENERgy:STDDev?
<MeasType>
POWer:SWITching:RESult:ENERgy:WFMCount?
<MeasType>
Return the specified statistic result of the specified measurement type.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
EVTCount: number of measurement results in the long-term measurement
●
NPEak: negative peak value of the long-term measurement results
●
PPEak: positive peak value of the long-term measurement results
Power analysis (option R&S