Protocol analysis
R&S
®
RTO6
811
User Manual 1801.6687.02 ─ 05
Remote command:
CRC error ← Errors
Searches for a frame that has a mismatch of the Cyclic Redundancy Check (CRC)
value between the transmitting and receiving device.
Remote command:
Out of range error ← Errors
Searches for values that are out of range. This can be, for example a preamble error,
or invalid symbols in control blocks.
Remote command:
Zero terrnary symbol ← Errors
Searches for zero ternary symbol pairs (0-0).
Remote command:
SEARch:TRIGger:TBTO:ERRor:ZERO
13.19.5.2
1000BASE-T1 search results
To get search results, "Enable" the search. You can minimize, shift or close the search
dialog.
The search results are listed in the search result table and marked in the waveform by
blue lines.
For an introduction to search results, see:
●
Chapter 11.1.2, "Search results"
●
Chapter 11.4.2, "Display zoom settings"
Remote commands:
●
●
SEARch:RESult:TBTO:FRAMe<m>:TYPE?
●
SEARch:RESult:TBTO:FRAMe<m>:STATe?
●
SEARch:RESult:TBTO:FRAMe<m>:STARt?
●
SEARch:RESult:TBTO:FRAMe<m>:STOP?
●
SEARch:RESult:TBTO:FRAMe<m>:DESTaddress?
●
SEARch:RESult:TBTO:FRAMe<m>:SRCaddress?
●
SEARch:RESult:TBTO:FRAMe<m>:DATA?
●
SEARch:RESult:TBTO:FRAMe<m>:CRC?
●
SEARch:RESult:TBTO:FRAMe<m>:NUMWords?
●
SEARch:RESult:TBTO:FRAMe<m>:FTYPe?
●
SEARch:RESult:TBTO:FRAMe<m>:DSYMbol?
Ethernet 1000BASE-T1 (option R&S