12 - 31
Chapter 12 Expansion Control
Speed during continuous operation to torque control mode
The speed during the continuous operation to torque control mode is controlled
with an absolute value of the value set in "
Cd.147
Speed limit value at continuous
operation to torque control mode
" as command speed. When the speed reaches the
absolute value of "
Cd.147
Speed limit value at continuous operation to torque control
mode
", "Speed limit" ("
Md.108
Servo status
" (low-order buffer memory address): b4)
turns ON.
Buffer memory address (Low-order)
LD77MS2/LD77MS4
LD77MS16
Md.108
Servo status
: b4
876+100n 2476+100n
n: Axis No.-1
In addition, "
Cd.147
Speed limit value at continuous operation to torque control mode
" is
limited with "
Pr.8
Speed limit value
". If the command speed exceeding the speed
limit value is set, a warning "Speed limit value over" (warning code: 501) occurs,
and the operation is controlled with the speed limit value.
POINT
The actual motor speed may not reach the command speed depending on the
machine load situation during the continuous operation to torque control mode.
Current feed value during continuous operation to torque control mode
"
Md.20
Current feed value
", "
Md.21
Machine feed value
" and "
Md.101
Real current
value
" are updated even in the continuous operation to torque control mode. If the
current feed value exceeds the software stroke limit, the error "Software stroke
limit +" (error code: 507) or "Software stroke limit -" (error code: 508) occurs and
the operation switches to the position control mode. Invalidate the software stroke
limit to execute one-way feed.
Summary of Contents for MELSEC-L Series
Page 2: ......
Page 30: ...MEMO ...
Page 70: ...2 10 Chapter 2 System Configuration MEMO ...
Page 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Page 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Page 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Page 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Page 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Page 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Page 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Page 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Page 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 440: ...MEMO ...
Page 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Page 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Page 656: ...11 32 Chapter 11 Manual Control MEMO ...
Page 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Page 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Page 866: ...14 68 Chapter 14 Common Functions MEMO ...
Page 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Page 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Page 1036: ...Appendix 88 Appendices MEMO ...