5 - 103
Chapter 5 Data Used for Positioning Control
Da.11
Shape
Set whether to carry out only the local "block start data" and then end control, or to
execute the "block start data" set in the next point.
Setting value
Setting details
0 : End
Execute the designated point's "block start data", and then complete the control.
1 : Continue
Execute the designated point's "block start data", and after completing control, execute the next
point's "block start data".
Da.12
Start data No.
Set the "positioning data No." designated with the "block start data".
Da.13
Special start instruction
Set the "special start instruction" for using "high-level positioning control". (Set how
to start the positioning data set in "
Da.12
Start data No.
".)
Setting value
Setting details
00H: Block start
(Normal start)
Execute the random block positioning data in the set order with one start.
01H: Condition start
Carry out the condition judgment set in "condition data" for the designated positioning data, and
when the conditions are established, execute the "block start data". If not established, ignore
that "block start data", and then execute the next point's "block start data".
02H: Wait start
Carry out the condition judgment set in "condition data" for the designated positioning data, and
when the conditions are established, execute the "block start data". If not established, stop the
control (wait) until the conditions are established.
03H: Simultaneous
start
Simultaneous execute (output command at same timing) the positioning data with the No.
designated for the axis designated in the "condition data".
Up to four axes can start simultaneously.
04H: Repeated start
(FOR loop)
Repeat the program from the block start data with the "FOR loop" to the block start data with
"NEXT" for the designated number of times.
05H: Repeated start
(FOR condition)
Repeat the program from the block start data with the "FOR condition" to the block start data
with "NEXT" until the conditions set in the "condition data" are established.
06H: NEXT start
Set the end of the repetition when "04H: Repetition start (FOR loop)" or "05H: Repetition start
(FOR condition)" is set.
Refer to Chapter 10 "High-Level Positioning Control" for details on the control.
Da.14
Parameter
Set the value as required for "
Da.13
Special start instruction
".
Da.13
Special start instruction
Setting value
Setting details
Block start (Normal start)
–
Not used. (There is no need to set.)
Condition start
1 to 10
Set the condition data No. (Data No. of
"condition data" is set up for the
condition judgment.)
Wait start
Simultaneous start
Repeated start (FOR loop)
0 to 255
Set the number of repetitions.
Repeated start (FOR condition)
1 to 10
Set the condition data No. (Data No. of
"condition data" is set up for the
condition judgment.)
Summary of Contents for MELSEC-L Series
Page 2: ......
Page 30: ...MEMO ...
Page 70: ...2 10 Chapter 2 System Configuration MEMO ...
Page 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Page 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Page 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Page 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Page 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Page 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Page 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Page 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Page 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 440: ...MEMO ...
Page 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Page 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Page 656: ...11 32 Chapter 11 Manual Control MEMO ...
Page 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Page 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Page 866: ...14 68 Chapter 14 Common Functions MEMO ...
Page 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Page 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Page 1036: ...Appendix 88 Appendices MEMO ...
Page 1039: ......