5 - 62
Chapter 5 Data Used for Positioning Control
Pr.52
OPR deceleration time selection
Set which of "deceleration time 0 to 3" to use for the deceleration time during OPR.
0 : Use the value set in "
Pr.10
Deceleration time 0
".
1 : Use the value set in "
Pr.28
Deceleration time 1
".
2 : Use the value set in "
Pr.29
Deceleration time 2
".
3 : Use the value set in "
Pr.30
Deceleration time 3
".
Pr.53
OP shift amount
Set the amount to shift (move) from the position stopped at with machine OPR.
The OP shift function is used to compensate the OP stopped at with machine
OPR.
If there is a physical limit to the OP, due to the relation of the near-point dog
installation position, use this function to compensate the OP to an optimum
position.
OPR direction
When " OP
shift amount" is positive
Shift point
Shift point
When " OP
shift amount" is negative
Start point
Near-point dog signal
Zero signal
Pr.53
Pr.53
Pr.44
Pr.1
setting value
Value set with GX Works2
(unit)
Value set with sequence program
(unit)
0 : mm
-214748364.8 to 214748364.7 (
m)
-2147483648 to 2147483647 (
10
-1
m)
1 : inch
-21474.83648 to 21474.83647 (inch)
-2147483648 to 2147483647 (
10
-5
inch)
2 : degree
-21474.83648 to 21474.83647 (degree)
-2147483648 to 2147483647 (
10
-5
degree)
3 : PLS
-2147483648 to 2147483647 (PLS)
-2147483648 to 2147483647 (PLS)
Summary of Contents for MELSEC-L Series
Page 2: ......
Page 30: ...MEMO ...
Page 70: ...2 10 Chapter 2 System Configuration MEMO ...
Page 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Page 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Page 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Page 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Page 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Page 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Page 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Page 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Page 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 440: ...MEMO ...
Page 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Page 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Page 656: ...11 32 Chapter 11 Manual Control MEMO ...
Page 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Page 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Page 866: ...14 68 Chapter 14 Common Functions MEMO ...
Page 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Page 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Page 1036: ...Appendix 88 Appendices MEMO ...
Page 1039: ......