Chapter 6: Using the Web Interface
196
To swap the master and slave device:
In the Bridging mode, you can swap the master and slave devices by
simply disconnecting ALL cascading cables from them, and then
reconnecting cascading cables. No changes to software settings are
required.
In the Port Forwarding mode, you must follow the procedure below:
a.
Access the slave device that will replace the master device, and
set its role to 'Master', and correctly set the downstream
interface.
b.
Access the master device, set its role to 'Slave'.
c.
Swap the master and slave device now.
You must disconnect the LAN cable and ALL cascading
cables connected to the two devices first before swapping
them, and then reconnecting all cables.
To change the cascading mode applied to a chain:
1.
Access the last slave device, and change its cascading mode.
If the new cascading mode is 'Port Forwarding', you must also
set its role to 'Slave'.
2.
Access the second to last, third to last and so on until the first slave
device to change their cascading modes one by one.
3.
Access the master device, and change its cascading mode.
If the new cascading mode is 'Port Forwarding', you must also
set its role to 'Master', and correctly select the downstream
interface.
The following diagram indicates the correct sequence. 'N' is the final
one.
M = Master device
S = Slave device
Summary of Contents for Raritan SRC-0100
Page 114: ...Chapter 6 Using the Web Interface 102...
Page 291: ...Chapter 6 Using the Web Interface 279...
Page 301: ...Chapter 6 Using the Web Interface 289 6 Click Create to finish the creation...
Page 311: ...Chapter 6 Using the Web Interface 299...
Page 312: ...Chapter 6 Using the Web Interface 300 Continued...
Page 625: ...Appendix H RADIUS Configuration Illustration 613 Note If your SRC uses PAP then select PAP...
Page 630: ...Appendix H RADIUS Configuration Illustration 618 14 The new attribute is added Click OK...
Page 631: ...Appendix H RADIUS Configuration Illustration 619 15 Click Next to continue...