GD32W51x User Manual
532
2
CH1G
Channel 1’s capture or compare event generation
Refer to CH0G description
1
CH0G
Channel 0’s capture or compare event generation
This bit is set by softw are in order to generate a capture or compare event in channel
0, it is automatically cleared by hardw are. When this bit is set, the CH1IF flag is set,
the corresponding interrupt or DMA request is sent if enabled. In addition, if channel
1 is configured in input mode, the current value of the counter is captured in
TIMERx_CH0 CV register, and the CH0OF flag is set if the CH0IF flag w as already
high.
0: No generate a channel 1 capture or compare event
1: Generate a channel 1 capture or compare event
0
UPG
This bit can be set by softw are, and cleared by hardw are automatically. When this
bit is set, the counter is cleared if the center-aligned or up counting mode is selected,
else (dow n counting) it takes the auto-reload value. The prescaler counter is cleared
at the same time.
0: No generate an update event
1: Generate an update event
Channel control register 0 (TIMERx_CHCTL0)
Address offset: 0x18
Reset value: 0x0000 0000
This register has to be accessed by word (32-bit).
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CH1COM
CEN
CH1COMCTL[2:0]
CH1COM
SEN
CH1COM
FEN
CH1MS[1:0]
CH0COM
CEN
CH0COMCTL[2:0]
CH0COM
SEN
CH0COM
FEN
CH0MS[1:0]
CH1CAPFLT[3:0]
CH1CAPPSC[1:0]
CH0CAPFLT[3:0]
CH0CAPPSC[1:0]
rw
rw
rw
rw
rw
rw
Output com pare m ode:
Bits
Fields
Descriptions
31:16
Reserved
Must be kept at reset value.
15
CH1COMCEN
Channel 1 output compare clear enable
Refer to CH0COMCEN description
14:12
CH1COMCTL[2:0]
Channel 1 compare output control
Refer to CH0COMCTL description
11
CH1COMSEN
Channel 1 output compare shadow enable