Figure 17-34. General Level 0 timer block diagram
=1
0
0
0
0
Input Logic
Synchronizer&Filter
&Edge Detector
Edge selector
Prescaler
Trigger processor
Trigger Selector&Counter
Quadrate Decoder
Slave mode processor
Counter
External Trigger
Input logic
Polarity selection
Edge detector
Prescaler
Filter
TIMERx_CHxCV
Register /Interrupt
Register set and update
Interrupt collector and
controller
APB BUS
CK_TI MER
CH0_I N
CH1_I N
CH2_I N
CH3_I N
CI0
ITI0
ITI1
ITI2
ITI3
ETI
CAR
Output Logic
generation of outputs signals in
compare, PWM,and mixed modes
according to initialization, software
output mask, and polarity control
CH0_O
DMA controller
TIMERx_TRGO
.
Interrupt
CH1_O
CH2_O
CH3_O
U
p
d
a
te
T
ri
g
g
e
r
C
a
p
/C
o
m
DMA REQ/ ACK
TIMERx_CH0
TIMERx_CH1
TIMERx_CH2
TIMERx_CH3
TIMERx_TG
TIMERx_UP
PSC
PSC_CLK
TIMER_CK
req en/direct req set
ETIFP
17.2.4.
Function overview
Clock selection
The general level0 TIMER has the capability of being clocked by either the CK_TIMER or an
alternate clock source controlled by SMC (TIMERx_SMCFG bit [2:0]).
SMC [2:0] == 3’b000. Internal timer clock CK_TIMER which is from module RCU.
The default internal clock source is the CK_TIMER used to drive the counter prescaler when
the slave mode is disabled (SMC [2:0] == 3
’
b000). When the CEN is set, the CK_TIMER will
be divided by PSC value to generate PSC_CLK.
In this mode, the TIMER_CK, driven counter
’
s prescaler to count, is equal to CK_TIMER
which is from RCU.
If the slave mode controller is enabled by setting SMC [2:0] in the TIMERx_SMCFG register
to an available value including 0x1, 0x2, 0x3 and 0x7, the prescaler is clocked by other clock
sources selected by the TRGS [2:0] in the TIMERx_SMCFG register and described as follows.
When the slave mode selection bits SMC [2:0] are set to 0x4, 0x5 or 0x6, the internal clock
TIMER_CK is the counter prescaler driving clock source.