GD32W51x User Manual
544
31:0
CH1VAL[31:0]
Capture or compare value of channel1
When channel 1 is configured in input mode, this bit-filed indicates the counter value
corresponding to the last capture event. And this bit-filed is read-only.
When channel 1 is configured in output mode, this bit-filed contains value to be
compared to the counter. When the corresponding shadow register is enabled, the
shadow register updates every update event.
Channel 1 capture/compare value register (TIMERx_CH1CV) (x=3,4)
Address offset: 0x38
Reset value: 0x0000 0000
This register has to be accessed by word (32-bit).
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CH1VAL[15:0]
rw
Bits
Fields
Descriptions
31:16
Reserved
Must be kept at reset value.
15:0
CH1VAL[15:0]
Capture or compare value of channel1
When channel 1 is configured in input mode, this bit-filed indicates the counter value
corresponding to the last capture event. And this bit-filed is read-only.
When channel 1 is configured in output mode, this bit-filed contains value to be
compared to the counter. When the corresponding shadow register is enabled, the
shadow register updates every update event.
Channel 2 capture/compare value register (TIMERx_CH2CV) (x=1,2)
Address offset: 0x3C
Reset value: 0x0000 0000
This register has to be accessed by word(32-bit)
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
CH2VAL[31:16]
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CH2VAL[15:0]
rw
Bits
Fields
Descriptions