GD32W51x User Manual
431
22
PM
AM/PM mark
0:AM or 24-hour format
1:PM
21:20
HRT[1:0]
Hour tens in BCD code
19:16
HRU[3:0]
Hour units in BCD code
15
Reserved
Must be kept at reset value.
14:12
MNT[2:0]
Minute tens in BCD code
11:8
MNU[3:0]
Minute units in BCD code
7
Reserved
Must be kept at reset value.
6:4
SCT[2:0]
Second tens in BCD code
3:0
SCU[3:0]
Second units in BCD code
16.4.14.
Date of time stamp register (RTC_DTS)
Address offset: 0x34
Backup domain reset value: 0x0000 0000
System reset: no effect
This register will record the calendar date when TSF is set to 1.
This register can be write-protected to prevent
non-secure access or non-privileged access
Reset TSF bit will also clear this register.
This register has to be accessed by word (32-bit)
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DOW[2:0]
MONT
MONU[3:0]
Reserved
DAYT[1:0]
DAYU[3:0]
r
r
r
r
r
Bits
Fields
Descriptions
31:16
Reserved
Must be kept at reset value.
15:13
DOW[2:0]
Days of the w eek
12
MONT
Month tens in BCD code
11:8
MONU[3:0]
Month units in BCD code
7:6
Reserved
Must be kept at reset value.
5:4
DAYT[1:0]
Day tens in BCD code
3:0
DAYU[3:0]
Day units in BCD code