Chapter 9: Using the Command Line Interface
633
▪
outletgroup modify 2 members 3-5,8,10
-- OR --
▪
outletgroup modify 2 members 3,4,5,8,10
Powering On/Off/Cycle Outlet Groups
This section applies to outlet-switching capable models only.
You must perform this operation in the
administrator mode
. See
Different CLI
Modes and Prompts
(on page 527).
Power on one outlet group:
#
power outletgroup <ID> on
Power off one outlet group:
#
power outletgroup <ID> off
Power cycle one outlet group:
#
power outletgroup <ID> cycle
To quicken the operation, you can add the parameter "/y" to the end of the
command, which confirms the operation.
For example:
#
power outletgroup <ID> off /y
If you entered the command without "/y", a message appears, prompting you
to confirm the operation. Then:
▪
Type
y
to confirm the operation, OR
▪
Type
n
to abort the operation
Variables:
•
<ID> is an outlet group's index number.
Inlet Configuration Commands
An inlet configuration command begins with
inlet
. You can configure an inlet by
using the inlet configuration command.
Содержание Raritan PX3TS
Страница 4: ......
Страница 6: ......
Страница 20: ......
Страница 52: ...Chapter 3 Initial Installation and Configuration 32 Number Device role Master device Slave 1 Slave 2 Slave 3...
Страница 80: ...Chapter 4 Connecting External Equipment Optional 60...
Страница 109: ...Chapter 5 PDU Linking 89...
Страница 117: ...Chapter 5 PDU Linking 97...
Страница 440: ...Chapter 7 Using the Web Interface 420 If wanted you can customize the subject and content of this email in this action...
Страница 441: ...Chapter 7 Using the Web Interface 421...
Страница 464: ...Chapter 7 Using the Web Interface 444...
Страница 465: ...Chapter 7 Using the Web Interface 445 Continued...
Страница 746: ...Appendix A Specifications 726...
Страница 823: ...Appendix I RADIUS Configuration Illustration 803 Note If your PX3TS uses PAP then select PAP...
Страница 824: ...Appendix I RADIUS Configuration Illustration 804 10 Select Standard to the left of the dialog and then click Add...
Страница 825: ...Appendix I RADIUS Configuration Illustration 805 11 Select Filter Id from the list of attributes and click Add...
Страница 828: ...Appendix I RADIUS Configuration Illustration 808 14 The new attribute is added Click OK...
Страница 829: ...Appendix I RADIUS Configuration Illustration 809 15 Click Next to continue...
Страница 860: ...Appendix J Additional PX3TS Information 840...
Страница 890: ...Appendix K Integration 870 3 Click OK...
Страница 900: ......