Chapter 7: Using the Web Interface
406
Send Sensor Report
You may set the PX3TS so that it automatically reports the latest readings or
states of one or multiple sensors by sending a message or email or simply
recording the report in a log. These sensors can be either internal or
environmental sensors listed below.
•
Inlet sensors, including RMS current, RMS voltage, active power, apparent
power, power factor and active energy.
•
Outlet state sensors, which are available on outlet-switching capable PDUs
only.
•
Overcurrent protector sensors, including RMS current and tripping state.
•
Peripheral device sensors, which can be any Raritan environmental sensor
packages connected to the PX3TS, such as temperature or humidity
sensors.
An example of this action is available in the section titled
Send Sensor Report
Example
(on page 419).
Operation:
1.
Choose Device Settings > Event Rules >
.
2.
Select 'Send sensor report' from the Action list.
3.
In the 'Destination actions' section, select the method(s) to report sensor
readings or states. The number of available methods varies, depending on
how many messaging actions have been created.
The messaging action types include:
▪
Log event message
▪
Syslog message
▪
Send email
▪
Send SMS message
4.
If no messaging actions are available, create them now. See
Available
Actions
(on page 394).
a.
To select any methods, select them one by one in the Available field.
To add all available methods, simply click Select All.
b.
To delete any methods, click a method's
in the Selected field.
To remove all methods, simply click Deselect All.
5.
In the 'Available sensors' field, select the desired target's sensor.
a.
Click the first
to select a target component from the list.
Содержание Raritan PX3TS
Страница 4: ......
Страница 6: ......
Страница 20: ......
Страница 52: ...Chapter 3 Initial Installation and Configuration 32 Number Device role Master device Slave 1 Slave 2 Slave 3...
Страница 80: ...Chapter 4 Connecting External Equipment Optional 60...
Страница 109: ...Chapter 5 PDU Linking 89...
Страница 117: ...Chapter 5 PDU Linking 97...
Страница 440: ...Chapter 7 Using the Web Interface 420 If wanted you can customize the subject and content of this email in this action...
Страница 441: ...Chapter 7 Using the Web Interface 421...
Страница 464: ...Chapter 7 Using the Web Interface 444...
Страница 465: ...Chapter 7 Using the Web Interface 445 Continued...
Страница 746: ...Appendix A Specifications 726...
Страница 823: ...Appendix I RADIUS Configuration Illustration 803 Note If your PX3TS uses PAP then select PAP...
Страница 824: ...Appendix I RADIUS Configuration Illustration 804 10 Select Standard to the left of the dialog and then click Add...
Страница 825: ...Appendix I RADIUS Configuration Illustration 805 11 Select Filter Id from the list of attributes and click Add...
Страница 828: ...Appendix I RADIUS Configuration Illustration 808 14 The new attribute is added Click OK...
Страница 829: ...Appendix I RADIUS Configuration Illustration 809 15 Click Next to continue...
Страница 860: ...Appendix J Additional PX3TS Information 840...
Страница 890: ...Appendix K Integration 870 3 Click OK...
Страница 900: ......