R&S ZVL
Programming Examples
Basic Tasks
Operating Manual 1303.6580.32-05
574
entire sweep range
CALCulate1:LIMit:DATA 2, 4500000000, 5000000000, -10, -15
CALCulate1:LIMit:DATA 2, 5000000000, 5500000000, -15, -10 //
define two segments for the lower
limit line
//
// Display the limit line and perform the limit check.
CALCulate1:LIMit:DISPlay:STATe ON
CALCulate1:LIMit:STATe ON; FAIL? /
if the trace is failed; the response is 1.
//
//
Check the result on the local screen
// Go to local
SYSTem:DISPlay:UPDate ONCE
//
//
Check the result in the
Define Limit Line
dialog
// The
Define Limit Line
dialog gives an overview of the limit line segments of the active trace.